Temperature Measurement and Calibration
Objectives:
⚬ To e xp lore the func tiona lity of the p la tinum re sista nc e
the rm om e te r (PRT) a nd a sse ss its line a rity.
⚬ To e va lua te the line a rity a nd p re c ision of liq uid - fille d g la ss,
ga s (va por) pre ssure, a nd bi- m e ta l d e vic e s throug h
c a lib ra tion a g a inst a re fe re nc e se nsor.
⚬ To e xa m ine the op e ra tiona l p rinc ip le s a nd line a rity of the NTC
the rm istor a nd the rm oc oup le s.
⚬ To c om p a re the line a rity of J a nd K typ e the rm oc oup le s.
Equipment:
⚬ PRT
⚬ bi- m eta l d evic e s
⚬ NTC the rm istor
⚬ J a nd K typ e the rm oc oup le s
ROTATIONAL SPEED FOLLOWER CONTROL WITH PID CONTROLLER
(OPEN- ENDED)
OBJECTIVES:
To te st a nd e va lua te the rota tiona l sp e e d c ontrol with a PID
c ontrolle r
SENSORS AND INSTRUMENTATION SYSTEM
OBJECTIVES:
⚬ To a sse ss the p e rform a nc e of stra in g a ug e s for
m ea surem ent of line a r d isp la c em ent
⚬ To und e rsta nd the use of stra in g a ug e s in a p ote ntia l
d ivid e r, q ua rte r, ha lf a nd full b rid g e c onfig ura tions a nd
the re la tive se nsitivitie s in e a c h c a se
⚬ To a sse ss the sourc e s of e rror in using stra in g a ug e s to LAB SUPERVISOR
m ea sure d isp la c e m e nt IR. DR. WONG WEIRU
weiru@um .edu .my
EQUIPMENT: PIC LAB
⚬ Stra in g a ug e s MOHD AKMAL RIZUAN BIN ABD
RAHMAN
mohdakmalrizuan@um .edu .my